Kissing stents ultrasound
Web4 mei 2015 · The mean diameter of implanted stents in the single-stent group was slightly smaller than that in the kissing-stents group (8.2 ± 0.9 vs 8.9 ± 1.8 mm; P = .046). The single-stent group required less frequent bilateral femoral artery puncture than the kissing-stents group (55% vs 100%; P < .001). Web27 sep. 2015 · All the patients met the criteria of using Kissing-stenting treatment as the following: (1) vascular color Doppler ultrasound showed hypoechoic or admixture-echoic signs at the occlusion sites in common iliac artery occlusions despite absence of severe calcification; (2) no anchoring (landing zone) occurred at aorta-iliac junction or proximal …
Kissing stents ultrasound
Did you know?
Web1 nov. 2024 · The bare metal stents used included Venovo and Vici stents. The nominal size of the angioplasty balloons used ranged from 8 to 12 mm. Two patients had … WebKissing-balloon dilation was performed using two 5.0 mm balloons. A 7.0 × 37 mm Express LD balloon-expandable stent was deployed from the aorta to the left CIA …
Web31 mrt. 2015 · Self-expandable kissing stents can be used successfully with comparable patency for endovascular treatment of symptomatic atherosclerotic occlusive lesions in the aortic bifurcation area. ... (CFA) punctures, in most cases with 6–8 French introducers. The CFA punctures were performed under ultrasound guidance, ... WebBackground: Double kissing (DK) crush approach for patients with coronary bifurcation lesions, particularly localized at distal left main or lesions with increased …
WebWe report a case of the simultaneous kissing stents (SKS) technique using a drug-eluting stent (DES) as a bailout strategy in acute left main coronary artery occlusion with a true … Web12 apr. 2011 · The “kissing balloon” technique was then attempted by simultaneously inflating both branches using the same balloons, but more than a 70% residual stenosis persisted in each branch. Two stents were finally placed in a “kissing” way through the main renal artery.
WebA review was performed of the literature of the last 5 years regarding the endovascular treatment of aortoiliac and iuxtarenal TASC II C& D lesions with covered balloon …
Web1 aug. 2003 · METHODS:balloon- or self-expanding kissing stents, with or without predilatation depending upon the nature of the disease, were inserted via bilateral retrograde femoral artery punctures. Clinical examination, ABPI, exercise testing and duplex ultrasound were performed at 1, 3, 6, and 12 months, and then annually. qgis change map projectionWebObjectives: Intravascular ultrasound (IVUS) was performed to investigate the impact of kissing balloon inflation (KBI) on the main vessel (MV) stent volume, area, and symmetry after side-branch (SB) dilation in patients with coronary bifurcation lesions (CBL). Background: It remains controversial whether KBI would restore the MV stent area and … qgis channel networkWeb1 jul. 2012 · The kissing-stent technique is a viable option for ensuring inferior mesenteric artery patency when treating distal aortic lesions by endovascular means in patients with asymptomatic multivessel mesenteric artery disease. Case report qgis changeattributevalueWebObjectives: Intravascular ultrasound (IVUS) was performed to investigate the impact of kissing balloon inflation (KBI) on the main vessel (MV) stent volume, area, and … qgis changer ordre champWebKissing stents were deployed and postdilatation was performed. Lower two sections are ultrasound images of (A) a proximal stent segment and (B) bifurcation stent carina. qgis check if point in polygonWeb27 jun. 2024 · The KBI (kissing balloon inflation) technique is considered the default strategy for the two-stent approach in real world practice. Studies comparing KBI and No-KBI in patients undergoing the one-stent approach have reported conflicting results. The meta-analysis was performed to compare the clinical outcomes of the KBI strategy and … qgis check if lines are connectedWeb1 nov. 2024 · SVC reconstruction with kissing self-expanding stents has been described, although limited to case reports and small case series. 24, 25 Alternately, a Y-stent configuration using fenestrated self-expanding stents could also be considered. 26 Finally, a three-stent configuration with kissing stent or stent grafts placed into a trunk SVC stent … qgis changer projection